Back to top

Testing Instruments

This range of Testing Instruments has extensive applications in pharmaceutical arena and chemical laboratory. Application of these apparatus depends on their mechanism and design. These are mainly used to determine heart beat and body temperature of patient, to verify hardness of tablet, to check light absorption rate of specific chemicals and so on. Offered array of Testing Instruments has been designed as per global norms. Accurate testing method, high durability, ergonomic design, long working life, utilization of advanced technology and precise diameter are the key characteristics of this assortment of apparatus. Quality of these testing solutions has been assessed on the basis of their error free operation, design, durability, output, strength, functional stability, resistant properties, testing mode, service life and diameter.

DIGITAL FRIABILITY TEST APPARATUS

MOQ : 1 Piece

  • Equipment Type
  • Digital Friability Test Apparatus
  • Accuracy
  • 1 Revolution
  • Application
  • Tablet/Capsule Friability Testing
  • Automation Grade
  • Automatic
  • Capacity
  • Up to 100 tablets per drum
  • Control Mode
  • Digital Microprocessor Based
  • Display Type
  • 6-Digit Bright LED Display
  • Features
  • Programmable Timer, Automatic drum stop, Audible alarm on test completion
  • Frequency
  • 50 Hz
  • Hardness
  • Not Measured by this device
  • Humidity
  • Ambient or as per test condition
  • Interface Type
  • Membrane Keyboard Interface
  • Machine Weight
  • Approx. 12 kg
  • Max Height
  • 170 mm (including drum)
  • Measuring Range
  • 0-999 rev/min
  • Mounting Type
  • Bench Top
  • Number of Specimens
  • 1 or 2 drums (dual operation supported)
  • Operating Voltage
  • 230V AC
  • Port Size
  • Single / Dual Drum - 100 mm or as per USP/EP/IP
  • Power Supply
  • 230V 10% AC, 50 Hz
  • Resolution
  • 1 Revolution
  • Response Time
  • Instantaneous (Digital Display)
  • Specimen Size
  • Tablets up to 13 mm dia (standard as per pharmacopoeia)
  • Temperature
  • Ambient (5C-40C) or as specified
  • Test Range
  • 0-999 revolutions
  • Test Speed
  • 25 rpm 1 rpm (standard); adjustable
  • Test Stroke
  • 360 drum rotation
  • Usage
  • Pharmaceutical Laboratory Testing

Tablet Hardness Tester

  • Equipment Type
  • Tablet Hardness Tester
  • Accuracy
  • 0.5% F.S.
  • Application
  • To test tablet crushing strength (hardness)
  • Automation Grade
  • Manual/Semi-Automatic
  • Capacity
  • Up to 500 N
  • Control Mode
  • Manual / Digital
  • Display Type
  • Digital LCD
  • Features
  • LED display, accurate measurement, robust body
  • Frequency
  • 50 Hz
  • Hardness
  • Test up to 500 Newtons
  • Humidity
  • 20% - 80% RH
  • Interface Type
  • Digital interface
  • Machine Weight
  • 5 kg
  • Max Height
  • Approx. 300 mm
  • Measuring Range
  • 0 - 20 kg
  • Mounting Type
  • Bench-Top
  • Number of Specimens
  • One tablet at a time
  • Operating Voltage
  • 230 V AC, 50 Hz
  • Power Supply
  • 230 V AC, 50 Hz
  • Resolution
  • 0.01 kg
  • Response Time
  • Instantaneous
  • Specimen Size
  • 2 20 mm
  • Temperature
  • 10C 40C
  • Test Range
  • 2 20 mm (tablets)
  • Test Speed
  • Adjustable upto 60 tablets/hour
  • Test Stroke
  • Up to 20 mm
  • Test Width
  • Standard for pharmaceutical tablets
  • Usage
  • Pharmaceutical Laboratory Testing

Cleaveland Flash Point and Fire Point Apparatus

  • Equipment Type
  • Flash & Fire Point Apparatus
  • Accuracy
  • 1C
  • Application
  • Determining flash and fire points of petroleum products
  • Automation Grade
  • Manual
  • Capacity
  • 75 ml cup
  • Control Mode
  • Manual
  • Display Type
  • Analog or dial thermometer
  • Features
  • Heavy-gauge brass cup, energy regulator, high quality insulation, manual flame application, flame exposure shutter
  • Frequency
  • 50 Hz
  • Gas Pressure
  • Atmospheric or as recommended
  • Humidity
  • Up to 80% RH (non-condensing)
  • Machine Weight
  • Approx. 6.5 kg
  • Max Height
  • Approx. 350 mm
  • Measuring Range
  • Ambient to 370C
  • Mounting Type
  • Bench-top
  • Number of Specimens
  • Single specimen
  • Operating Voltage
  • 230 V AC
  • Port Size
  • Standard size for burner port
  • Power Supply
  • 230 V, 50 Hz AC
  • Resolution
  • 1C
  • Response Time
  • Immediate (manual observation)
  • Specimen Size
  • 75 ml (standard test cup)
  • Temperature
  • Ambient to 370C
  • Test Range
  • Ambient to 370C
  • Test Speed
  • Manual operation
  • Test Width
  • Standard: accommodates test cup
  • Usage
  • Laboratory/Testing Petroleum Products

Spectrophotometer

  • Equipment Type
  • Spectrophotometer
  • Accuracy
  • 0.5% T at 1A
  • Application
  • Qualitative & Quantitative analysis in chemical, clinical, pharmaceutical, environmental, biochemical applications
  • Automation Grade
  • Semi-Automatic
  • Control Mode
  • Manual / Digital
  • Display Type
  • Digital LCD Display
  • Features
  • Automatic wavelength setting, wide spectral range, user calibration, data storage, easy maintenance
  • Frequency
  • 50-60 Hz
  • Humidity
  • 80% RH (non-condensing)
  • Interface Type
  • RS232 / USB (optional)
  • Machine Weight
  • Approx. 8 kg
  • Max Height
  • 140 mm
  • Measuring Range
  • 0 3.0 Absorbance
  • Mounting Type
  • Benchtop
  • Number of Specimens
  • Single or multi-position (with optional accessories)
  • Operating Voltage
  • 220 V AC 10%, 50 Hz
  • Port Size
  • Standard 10 mm cuvette holder
  • Power Supply
  • 220 V AC, 50 Hz
  • Resolution
  • 0.1 nm
  • Response Time
  • Within 1 second
  • Specimen Size
  • Up to 10 mm path length
  • Temperature
  • Operating: 10 to 40
  • Test Range
  • 1901100 nm
  • Test Speed
  • 500 nm / min (variable)
  • Test Stroke
  • Unlimited (continuous spectral scan)
  • Test Width
  • 1 cm (standard cuvette width)
  • Usage
  • Spectral analysis of liquid samples

E.C.G. Machine

  • Equipment Type
  • E.C.G. Machine
  • Accuracy
  • 2%
  • Application
  • Cardiac diagnostic / Patient monitoring
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • Memory for 100 recordings
  • Control Mode
  • Manual / Auto
  • Display Type
  • LCD Digital display
  • Features
  • Thermal printer, Digital filters, Lead-off detection, Rechargeable battery
  • Frequency
  • 50/60 Hz
  • Humidity
  • 80% RH
  • Interface Type
  • RS232 / USB
  • Machine Weight
  • Approx. 2.5 kg
  • Measuring Range
  • 5 mV
  • Mounting Type
  • Tabletop / Portable
  • Number of Specimens
  • 1 Patient / Test
  • Operating Voltage
  • 110V-240V AC, 50/60Hz
  • Port Size
  • Standard 6-lead / 12-lead ECG cable port
  • Power Supply
  • 220V / 50Hz AC or built-in rechargeable battery
  • Resolution
  • 12 bit
  • Response Time
  • Instant (under 2 sec)
  • Specimen Size
  • Adult & Pediatric
  • Temperature
  • 5C 40C
  • Test Range
  • 0.05 150 Hz
  • Test Speed
  • 25 mm/s, 50 mm/s
  • Test Width
  • 50 mm
  • Usage
  • Hospital, Clinic, Diagnostic Center

Pfizer Type Tablet Hardness Tester

  • Equipment Type
  • Tablet Hardness Tester
  • Accuracy
  • 0.1 kg
  • Application
  • Measuring breaking point or hardness of tablets
  • Automation Grade
  • Manual
  • Capacity
  • 20 Kg
  • Control Mode
  • Hand Operated
  • Display Type
  • Analog (Dial Gauge)
  • Features
  • Lightweight, portable, easy to handle, robust metal construction
  • Hardness
  • Measures up to 20 Kg
  • Humidity
  • Up to 85% RH (Non-Condensing)
  • Machine Weight
  • Approx. 1.2 kg
  • Max Height
  • Approx. 120 mm including lever
  • Measuring Range
  • 0-20 kg (200 N)
  • Mounting Type
  • Handheld
  • Number of Specimens
  • Single tablet at a time
  • Power Supply
  • Not Required (Manual)
  • Resolution
  • 0.1 kg
  • Response Time
  • Instantaneous (Manual)
  • Specimen Size
  • Tablets up to 20 mm diameter or width
  • Temperature
  • 10C to 40C
  • Test Range
  • 0 - 20 Kg
  • Test Speed
  • Manual Operation
  • Test Stroke
  • Linear, up to 40 mm
  • Test Width
  • Up to 20 mm tablet diameter
  • Usage
  • Pharmaceutical laboratory, tablet production QA

Falling Ball Viscometer

  • Equipment Type
  • Falling Ball Viscometer
  • Accuracy
  • 1% of measured value
  • Application
  • Measurement of liquid viscosity by falling sphere method
  • Automation Grade
  • Manual
  • Capacity
  • Single-Tube Measuring System
  • Control Mode
  • Manual
  • Display Type
  • Analog or Digital Timer (external)
  • Features
  • Easy operation, corrosion resistant tube, calibrated glass balls
  • Humidity
  • Up to 90% RH non-condensing
  • Interface Type
  • Manual
  • Machine Weight
  • Approx. 7 kg
  • Max Height
  • Approx. 30 cm
  • Measuring Range
  • 3020,000 mPas (cP)
  • Mounting Type
  • Bench-top
  • Number of Specimens
  • 1
  • Power Supply
  • Not Required (manual operation)
  • Resolution
  • 0.01 mPas
  • Response Time
  • Within 1 s (displacement detection)
  • Specimen Size
  • Approx. 4050 ml
  • Temperature
  • Ambient or as per bath controller (range: 0100 C with external bath)
  • Test Range
  • 3020,000 mPas (sample viscosity)
  • Test Speed
  • Not Applicable (gravity driven)
  • Test Stroke
  • 180 mm (typical measuring tube length)
  • Usage
  • Laboratory analysis of viscosity

Digital Potentiometer

  • Equipment Type
  • Digital Potentiometer
  • Accuracy
  • 1% resistor tolerance
  • Application
  • Electronic adjustable resistance, Volume control, Sensor calibration
  • Automation Grade
  • Automatic
  • Capacity
  • 50mA max per channel
  • Control Mode
  • Digital
  • Display Type
  • No display, digital output
  • Features
  • Non-volatile memory, Low power, Compact size
  • Frequency
  • Up to 1 MHz (I2C/SPI clock)
  • Humidity
  • 0 to 85% RH (non-condensing)
  • Interface Type
  • I2C/SPI
  • Machine Weight
  • 1.2 kg
  • Max Height
  • 4.5 mm (package height)
  • Measuring Range
  • 1 k to 100 k
  • Mounting Type
  • Through Hole / SMD
  • Operating Voltage
  • 2.7V to 5.5V
  • Port Size
  • Standard 16-pin DIP/SOIC
  • Power Supply
  • 5V DC
  • Resolution
  • 8-bit (256 steps)
  • Response Time
  • 2 s (typical)
  • Temperature
  • -40C to +125C
  • Test Range
  • 1 k to 100 k (model dependent)
  • Usage
  • Programmable resistance for circuits

Digital TDS Meter

  • Equipment Type
  • Digital TDS Meter
  • Accuracy
  • 2% F.S.
  • Application
  • Water Purity Testing
  • Automation Grade
  • Manual
  • Control Mode
  • Manual
  • Display Type
  • LCD Digital Display
  • Features
  • Hold Function, Automatic Temperature Compensation (ATC), Auto-off, Low Battery Indicator
  • Humidity
  • < 80% RH
  • Interface Type
  • Direct Immersion
  • Machine Weight
  • 90 g
  • Measuring Range
  • 0-9990 ppm
  • Mounting Type
  • Handheld
  • Operating Voltage
  • 3V (2 x 1.5V button batteries)
  • Power Supply
  • 2 x 1.5V LR44 Button Cell Batteries
  • Resolution
  • 1 ppm
  • Response Time
  • < 2 Seconds
  • Temperature
  • 0-50C
  • Test Range
  • 0~9990 ppm
  • Usage
  • Measuring Total Dissolved Solids in Water

Clinical Thermometer

  • Equipment Type
  • Clinical Thermometer
  • Accuracy
  • 0.1C
  • Application
  • Measuring Body Temperature
  • Automation Grade
  • Manual
  • Capacity
  • 1 Unit
  • Control Mode
  • Manual
  • Display Type
  • Analog (Mercury-in-glass Scale)
  • Features
  • Mercury-filled, Clear Markings, Unbreakable construction
  • Hardness
  • Glass Body (Standard Hardness)
  • Humidity
  • 0-100% RH (Storage 10-85% RH)
  • Max Height
  • Approximately 120 mm
  • Measuring Range
  • 35C to 42C
  • Mounting Type
  • Hand-held / Portable
  • Number of Specimens
  • Single Specimen
  • Resolution
  • 0.1C
  • Response Time
  • About 1 Minute
  • Temperature
  • 35C to 42C
  • Test Range
  • 35C to 42C
  • Usage
  • Oral, Axillary, Rectal

Conductivity Meter

MOQ : 1 , , Piece

  • Color
  • white
  • Power Supply
  • Electric
  • Usage
  • Laboratory
  • Voltage
  • 220/230 Volt (v)
  • Weight
  • 2.5 Kilograms (kg)

Fann Viscometer

  • Application
  • to measure the viscosity of a liquid or a gas.
  • Features
  • Accuracy, Durable, Stable Performance
  • Material
  • Stainless Steel
  • Operate Method
  • Manual
  • Product Type
  • Fann Viscometer
  • Usage
  • Laboratory